Metadata for MicroLED Biosensor with Colloidal Quantum Dots and Smartphone detection -------------------------- Acquired by: Natalie Bruce Acquired at: Institute of Photonics, University of Strathclyde, Glasgow, UK -------------------------- Data corresponding to figures: - Figure 2b: contains data from "Figure2_raw_data.csv" sheet LIV data, measured voltage and optical output power of the microLED; - Figure 2c: contains data from "Figure2_raw_data.csv" sheet microLED PL and PLQdot 655 data, acquired on the spectrometer for the photoluminescene specturm of the microLED device and quantum dot solution measured voltage and optical output power of the microLED; - Figure 3a: contains data from "2022-03-18_guidingtest_2.csv" acquired using a spectrometer for spectral irradiance values; - Figure 3b: contains data from "2022-04-22_cutback2.csv" acquired using a spectrometer for spectral irradiance values; - Figure 6: contains data from folder "exposure time 250 ms current drive 120 mA" (source images taken with Samsung Galaxy S9) - Figure 7a and 7b: contains data from folders "exposure time 250 ms current drive 120 mA" and "exposure time 250 ms current drive 80mA" (source images taken with Samsung Galaxy S9) - Figure 8a and 8b: contains data from folders "exposure time 250 ms current drive 120 mA", "exposure time 50 ms current drive 120 mA" and "exposure time 1000 ms current drive 120 mA" (source images taken with Samsung Galaxy S9) NB. Figures 6, 7, and 8 use the NSB data for the zero-concentration data point on each graph. Data labelled 0nM is used for blank measurements.